wpl\s energyefficient products
Last Updated : GMT 05:17:37
Emiratesvoice, emirates voice
Emiratesvoice, emirates voice
Last Updated : GMT 05:17:37
Emiratesvoice, emirates voice

WPL\'s Energy-efficient products

Emiratesvoice, emirates voice

Emiratesvoice, emirates voice WPL\'s Energy-efficient products

London - Arabstoday

WPL has undertaken substantive research and development into energy saving options for their HiPAF submerged aerated filter sewage treatment range. This research has been undertaken with a view to reducing the whole life costs, energy consumption and carbon footprint, in line with the Water Utility 2020 initiatives. As part of WPL’s continuous product development, research work has taken place over the last 18 months on sites where WPL HiPAF plants have been installed, and provide real data that confirm assumptions made during the design and feasibility stages. The research work has been centred around the design of the aeration system and various scouring regimes, along with trials of different media configurations and blower efficiency. The HiPAF benefits from being a low maintenance treatment solution, with the emphasis on reducing moving mechanical parts within the hostile environment of the treatment plant. However, savings of between 15% and 50% on electricity consumption provide a significant reduction in whole life costs, particularly in higher population equivalent applications. Dual speed blowers utilising variable speed drives is one option that has had favourable reviews from clients, and other design efficiencies both with regard to blower design and media configuration have brought significant savings to some existing clientele. Product Specification WPL designed and provided a bespoke HiPAF sewage treatment plant which incorporated a below ground 150m³ primary tank complete with integral pump station, Modular SAF Units, Lamella settlement tank, and tertiary Microscreen filtration system. The total package combined efficient processing, reliability and a robust design, whilst minimising visual impact on the landscape. The Sewage Treatment Process The bespoke package effluent treatment plant at Beaconsfield MSA is designed to treat waste water from a maximum population equivalent of 3,800 based on the ammonia load of 30.4kg/d that was specified by the design consultants. As such, the air compressors have been sized to deliver sufficient air to supply oxygen for the nitrifiers responsible for removing the ammonia load, whilst simultaneously providing enough air to scour the biozone media and preventing the biofilm from becoming too thick and anaerobic. Only two compressors are ever running at any time. Concept Proposal Since commissioning Beaconsfield MSA effluent treatment plant in March 2009, flow data captured from site has revealed that the site is currently operating between 20-30% of full design load capacity. This has lead WPL to consider the impacts and consequences of attempting to reduce air supply in line with operating flows and loads as opposed to peak design flows and loads. The benefits to the customer would be significant savings on the electricity bills. The preferred method of reducing energy consumption at Beaconsfield MSA would be to reduce the air supply during periods of low activity and thus low flows. From a 24 hour intensive flow monitoring survey carried out on 20th May 2009, it was identified that between 11pm and 7am of the following morning, flow to the foul water treatment plant effectively stopped. During this period of time, it is proposed that the air supply to the biozones be reduced by 50%. This would be achieved by manipulating the air supply such that both actuators open simultaneously, allowing the air from a single compressor to deliver air to both process streams. This would involve reconfiguring the control panel accordingly. Benefits Shutting down one compressor on 8 hours per day would yield a saving of 144 units per day. Based on 10 pence per unit this could potentially yield a saving of over £5000 per year. Jerry Storer, Senior Operations Executive for Extra MSA stated: “WPL have completed significant research into the energy consumption of the HiPAF plant sited at our service station at M40, Beaconsfield. This research has proven that optimising the air supply to our system can be achieved without compromising our EA consent and has therefore saved us considerable costs on our electricity bills.” Currently WPL are working at the above level of electricity savings by reducing the air supply, although they are also researching the possibility of increasing this saving to up to £10000 per year by reducing the blower use again during the periods of low flow. Conclusion WPL researched sites where HiPAF Sewage Treatment plants have been installed to investigate how energy consumption could be reduced and therefore how cost savings could be made. Real data research allowed WPL to reduce the air supply to the plants therefore reducing the blower electricity usage, which has saved MSA Extra Services Ltd up to £5,000 a year. WPL are continuing their product development research into the blower efficiency of their sewage treatment plants whilst also looking at the design of the aeration system and various scouring regimes, along with trials of different media configurations.

Name *

E-mail *

Comment Title*

Comment *

: Characters Left

Mandatory *

Terms of use

Publishing Terms: Not to offend the author, or to persons or sanctities or attacking religions or divine self. And stay away from sectarian and racial incitement and insults.

I agree with the Terms of Use

Security Code*

wpl\s energyefficient products wpl\s energyefficient products

 



Name *

E-mail *

Comment Title*

Comment *

: Characters Left

Mandatory *

Terms of use

Publishing Terms: Not to offend the author, or to persons or sanctities or attacking religions or divine self. And stay away from sectarian and racial incitement and insults.

I agree with the Terms of Use

Security Code*

wpl\s energyefficient products wpl\s energyefficient products

 



GMT 22:17 2017 Monday ,25 September

Stephens crashes out of Wuhan Open

GMT 09:29 2011 Saturday ,03 September

Cristiano Ronaldo:\'I shut people up all year\'

GMT 09:37 2017 Tuesday ,21 November

Sixth Miss World win draws India level

GMT 12:24 2017 Tuesday ,21 November

SAGITTARIUS (November23rd-December21st)

GMT 10:21 2017 Wednesday ,18 October

Egypt’s former football official calls Cuper

GMT 00:49 2014 Saturday ,30 August

Daum to launch North Korean map service

GMT 12:23 2012 Sunday ,05 August

Afghanistan\'s National Museum regains treasures

GMT 17:04 2012 Friday ,09 March

Egypt verdict expected Sunday
 
 Emirates Voice Facebook,emirates voice facebook  Emirates Voice Twitter,emirates voice twitter Emirates Voice Rss,emirates voice rss  Emirates Voice Youtube,emirates voice youtube  Emirates Voice Youtube,emirates voice youtube

Maintained and developed by Arabs Today Group SAL.
All rights reserved to Arab Today Media Group 2021 ©

Maintained and developed by Arabs Today Group SAL.
All rights reserved to Arab Today Media Group 2021 ©

emiratesvoieen emiratesvoiceen emiratesvoiceen emiratesvoiceen
emiratesvoice emiratesvoice emiratesvoice
emiratesvoice
بناية النخيل - رأس النبع _ خلف السفارة الفرنسية _بيروت - لبنان
emiratesvoice, Emiratesvoice, Emiratesvoice